GPB60DGPB60D Ideal for facilities demanding high unit availability and reliability and requiring a "Green Engine" with low exhaust emissions in the 5 to 6 Mw power power range with significant thermal and electrical loads.
The GPB60D is a heavy duty industrial gas turbine package that offers electrical efficiency of 30% and an overall cogeneration CHP efficiency of 80.2%.  It is well suited  for use in areas requiring reduced emissions and electrical power ranging from 5 to 6 Mw's.  It is ideal for use in; shopping malls,  hospitals, universities,  high rise apartment/condo complexes,  office complexes / campuses with CHP  district heating and cooling loads, pharmaceuticals, electric utilities, aquariums,  city subway and commuter rail systems, and other facilities with significant thermal and electrical loads.
A Closer Look
The GPB60D is designed for use in Cogeneration applications requring a "Green Engine" providing from 5 to 6 MW's of electric power with reduced engine emissions.   It is ideal for  use in emissions regulated areas  for use in: Industrial process plants, Ethanol plants, Oil refineries, Hospitals, Hotels, Universities, City light rail and subway systems,  Office, apartments / condo complexes, and shopping malls with CHP district heating and cooling loads, pharmaceuticals, and other facilities with significant thermal and electrical loads.
  • Offers electrical efficiency of 29.2% and an cogeneration overall efficiency of 80.2%
  • Excellent overall heat rate
  • Design assures better RAM (reliability, availability, maintainability) and greater durability with 30,000HRS TBO (Time Between Overhauls)
  • NOx emissions of 25 ppmv and CO emissions of 50 ppmv (O2=15%)
  • Split case design allows for ease of inspection and maintenance on site, minimizing costly downtime
  • Cold end drive reduces load coupling thermal growth issues reducing maintenance.
  • Design is optimized for cogeneration applications
  • Dual fuel capability allows fuel fexibility burning both liquid and gas
  • Can be configured for either 50 Hz or 60 Hz electric systems
GT power plant performance - US Customary Units (Switch To Metric)
Inlet Air temp. Inlet air flow Electric Output Heat Rate fuel consumption Exhaust Temp. Exhaust Flow Steam Output
F lbs/ sec kW Btu/kwhr kW °F lbs/hr lbs/hr
59 47.38 5,280 11,840 18,456 1013 170,720 32,120
32 49.6 5,929 11,992 19,753 1003 179,280
86 42.84 4,507 13,142 16,453 1054 154,800
104 39.63 3,904 13,394 15,114 1085 143,280

Units Weights and Dimensions - US Customary Units (Switch To Metric)
Dimension (L,W,H) Weight (dry)
inches lbs
34 L x 6.5 w x 11.7 118,800


Standard Equipment
Special Features
< Go to Top >